A vertebral compression fracture is a compression of a vertebra, which occurs in the anterior portion of the vertebral body. In the treatment of compression-induced spinal fractures, there are two main directions of treatment: conservative treatment (bed rest, pharmacological treatment, orthosis) and minimally invasive surgical treatment - vertebroplasty, kyphoplasty, combined technology (uses implant and cement in the treatment method). Recently, coupled with technological advancements, the combined technology has become increasingly attractive to manufacturers of implantable medical devices. This article presents the combined technologies for minimally invasive surgical treatment that are currently available. Some of them have already been used to treat compression-induced spinal fractures for nearly a decade, sometimes being regarded as a reference for new medical devices entering the market.

Downloads

Download data is not yet available.

References

Mathis, J. M., Deramond, H., Belkoff, S. M. (2006). Percutaneous Vertebroplasty and Kyphoplasty, Springer, ISBN-13: 978-0387290782, New York.

https://spinalnewsinternational.com, Accessed: 2022-03-01.

http://images.rsna.org/index.html?doi=10.1148/radio

l.2017162100&fig=fig5a, Accessed: 2022-03-03.

https://www.aans.org/en/Patients/Neurosurgical-Conditions-and-Treatments/Vertebral-Compression-Fractures, Accessed: 2022-04-07

Lems, W. F., Paccou, J., Zhang, J., Fuggle, N. R., Chandran, M., Harvey, N. C., Cooper, C., Javaid, K., Ferrari, S., Akesson, K. E., International Osteoporosis Foundation Fracture Working Group (2021). Vertebral fracture: epidemiology, impact and use of DXA vertebral fracture assessment in fracture liaison services. Osteoporosis International volume 32, pages 399–411, Published: 21 January 2021.

https://www.physio-pedia.com/Lumbar_Compression

_Fracture, Accessed: 2022-04-07.

Shen, M., Kim, Y., (2007). Osteoporotic Vertebral Compression Fractures: A Review of Current Surgical Management Techniques. American Journal of Orthopedics (Belle Mead, N.J.) volume 36, pages 241-248, Published: 01 May 2007.

Teyssedou, S., Saget, M., Pries, P., (2014). Kyphopasty and vertebroplasty, Orthopaedics & Traumatology: Surgery & Research, Volume 100, Issue 1, Supplement, Pages S169-S179, Published: February 2014.

https://global.medtronic.com/xg-en/healthcare-

professionals/products/spinal-orthopaedic/vertebral- augmentation/kyphon-balloon.html, Accessed: 2022- 04-11

https://www.stryker.com/us/en/interventional-spine/

products/avaflex-balloon-system.html, Accessed: 2022-04-10

https://www.jnjmedtech.com/en-EMEA/product/

synflate-vertebral-balloon, Accessed: 2022-04-10

https://www.globusmedical.com/patient-education- musculoskeletal-system-conditions/procedures/

vertebral-augmentation/, Accessed: 2022-04-10

https://www.merit.com/merit-spine/spinal-

augmentation/vcf/arcadia-next-generation-balloon-catheter/, Accessed: 2022-04-11

https://www.youtube.com/watch?v=oFu9Yf2LzYw&l

ist=PLM22AATH0vHsLpyil0yerbnfxV4pUQ06W&index=8, Accessed: 2022-04-11

https://www.globenewswire.com/en/news-release/

/07/24/381952/8408/en/Alphatec-Spine-s-OsseoFix-Clinical-Study-Initiated.html, Accessed: 2022-04-11

https://www.youtube.com/watch?v=AAL5qt7xX_

A&list=PLM22AATH0vHsLpyil0yerbnfxV4pUQ06W&index=22, Accessed: 2022-04-11.

https://www.stryker.com/us/en/interventional-spine

/products/spinejack-system.html, Accessed: 2022-

-11.

https://izimed.com/kiva, Accessed: 2022-04-11.

https://dawamedical.com/products/ownage/,

Accessed: 2022-04-11.

https://www.youtube.com/watch?v=upl3aBXwFdo

&ab_channel=AtlanticSpineCenter, Accessed: 2022-04-11

https://www.spineart.com/products/tektona/,

Accessed: 2022-04-11.

Krüger, A., Bäumlein, M., Knauf, T. et al., (2021). Height and volume restoration in osteoporotic vertebral compression fractures: a biomechanical comparison of standard balloon kyphoplasty versus Tektona® in a cadaveric fracture model. BMC Musculoskeletal Disorders 22, 76. https://doi.org

/10.1186/s12891-020-03899-7, Accesed: 2022-04-11.

http://www.spinealignmedical.com/technology.html,

Accesed 2021-10-20

Vertebral body stenting system, Percutaneous treatment for vertebral body fractures – Surgical Technique Guide, Se_818940_Ab (036.001.638; Dsem/Spn/0614/0144) Eos: 176837-210514 Emea 06/21

Vanni D., Galzio R., Kazakova A., Pantalone A.,

Grillea G., Bartolo M., Salini V., Magliani V., (2016), Third-generation percutaneous vertebral augmentation systems, J Spine Surg, 2(1):13-20. doi: 10.21037/jss.2016.02.01.

https://www.spineguard.com/products-and-applic

ations/spine-products/pediguard-drilling-instruments, Accessed 2022-04-14

User Manual (Relea sed 2022-02-10) – Instruction

for Use of the Threaded PediGuard LP2-A036 - Version L

https://izimed.com/products/kiva-vcf-treatment-

system, Accessed 2022-04-14

https://www.youtube.com/watch?v=KgkMfZP2Ww

&ab_channel=CDASpineandBrain, Accessed 2022-04-14

Krüger, A., Oberkircher, L., Figiel, J., Floßdorf, F., Bolzinger, F., Noriega, D. C., Ruchholtz, S. (2015). Height restoration of osteoporotic vertebral compression fractures using different intravertebral reduction devices: a cadaveric study, The Spine Journal, Volume 15, Issue 5, (May 2015), 1092-1098.

Krüger, A., Baroud, G., Noriega, D., Figiel, J., Dorschel, C., Ruchholtz, S., Oberkircher L. (2013), Height restoration and maintenance after treating unstable osteoporotic vertebral compression fractures by cement augmentation is dependent on the cement volume used, Clinical Biomechanics, Volume 28, Issue 7, (Augudt 2013), 725-730.

Noriega, D., Marcia, S., Theumann, N., Blondel, B., Simon, A., Hassel, F., Maestretti, G., Petit, A., Weidle, P. A., Mandly, A. G., Kaya, J-M., Touta, A., Fuentes, S., Pflugmacher, R. (2019). A prospective international, randomized, noninferiority study comparing an implantable titanium vertebral augmentation device versus balloon kyphoplasty in the reduction of vertebral compression fractures (SAKOS study), The Spine Journal, 19, 1782-1795.

Ender, S. A., Gradl, G., Ender, M., Langner, S., Merk, H. R., Kayser R. (2014). Osseofix® System for Percutaneous Stabilization of Osteoporotic and Tumorous Vertebral Compression Fractures – Clinical and Radiological Results After 12 Months, Muskuloskelettales System, Fortschr Röntgenstr 2014; 186:380–387

Aebi, M., Maas, C., Treuheim, T. P.,Friedrich, H., Hans-Joachim Wilke. H-J. (2018). Comparative biomechanical study of a new transpedicular vertebral device and vertebroplasty for the treatment or prevention of vertebral compression fractures, Clinical Biomechanics, Volume 56, (July 2018), 40-45.

Anselmetti, G. C., Manca, A., Marcia,S., Chiara, G., Marini, S., Baroud, G., Regge D., Montemurro F. (2014). Vertebral Augmentation with Nitinol Endoprosthesis: Clinical Experience in 40 Patients with 1-Year Follow-up CardioVascular and Interventional Radiology Volume 37, 193–202 (February 2014).

Buchbinder, R., Johnston, R. V., Rischin, K. J., Homik, J., Jones, C. A., Golmohammadi, K., Kallmes, D.F. (2018). Percutaneous vertebroplasty for osteoporotic vertebral compression fracture. Cochrane Database of Systematic Reviews 2018, Issue 11. Art. No.: CD006349. https://doi.org/10.1002%2F14651858.CD006349.pub4

Ebeling, P. R., Akesson, K., Bauer, C. D., Buchbinder, R., Richard Eastell, R., Fink, A. H., Giangregorio, L., Guanabens, N., Kado, D., Kallmes, D., Katzman, W., Rodriguez, A., Wermers, R., Wilson H. A., Bouxsein L. M. (2019). The Efficacy and Safety of Vertebral Augmentation: A Second ASBMR Task Force Report, (2019). Journal of Bone and Mineral Research Vol. 34, No., pp 3–21, Published: 1, January 2019

Downloads

Published

2022-07-01

Issue

Section

Research Papers

Most read articles by the same author(s)

1 2 > >>